{"product_id":"nv120b3-2fe1t-vertical-pump-10-hp","title":"NV120B3-2FE1T Vertical Pump 10 HP","description":"\u003cdiv class=\"product-description\"\u003e\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eNV120B3-2FE1T Vertical Pump\u003c\/strong\u003e is a high-performance, multi-stage booster pump designed for a wide range of demanding industrial, commercial, and agricultural applications. With its compact, in-line design, this pump offers exceptional efficiency and ease of installation while delivering powerful and reliable performance.\u003c\/p\u003e\n\u003cp\u003eFeaturing a 10 HP motor and a flow capacity of up to 120 GPM, the NV120B3-2FE1T is engineered to handle pressures up to 232 PSI. Constructed from durable 304 stainless steel, it is corrosion-resistant and suitable for use in harsh environments. Maintenance-free cartridge mechanical seals and ANSI standard flanged connections ensure long-lasting performance and simple maintenance.\u003c\/p\u003e\n\u003cp\u003eCertified to meet NSF\/ANSI 61 and 372 standards, this pump is ideal for applications such as reverse osmosis, water boosting, filtration systems, hot and cold water circulation, and heat exchangers.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- SPECIFICATIONS --\u003e\n\u003c!-- COMMENTED OUT UNTIL DATA IS ACCURATE --\u003e\n\u003cp\u003e###\u003c\/p\u003e\n\u003c!-- \u003cdiv class=\"product-specifications\"\u003e\n\u003ch2\u003eSpecifications for NV120B3-2FE1T Vertical Pump\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"10\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNV120B3-2FE1T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlow Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 120 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e232 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterials\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBody:\u003c\/strong\u003e 304 Stainless Steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpellers:\u003c\/strong\u003e 304 Stainless Steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiffusers:\u003c\/strong\u003e 304 Stainless Steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShaft:\u003c\/strong\u003e 431 Stainless Steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Seals:\u003c\/strong\u003e Silicon Carbide\/Silicon Carbide\/EPDM\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\" ANSI 150# Flanged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 248°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSF\/ANSI 61 and 372\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eReverse Osmosis\u003c\/li\u003e\n\u003cli\u003eWater Boosting\u003c\/li\u003e\n\u003cli\u003eFiltration Systems\u003c\/li\u003e\n\u003cli\u003eHot and Cold Water Circulation\u003c\/li\u003e\n\u003cli\u003eHeat Exchangers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump Length:\u003c\/strong\u003e 32.42 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 151 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e --\u003e\n\n\u003c!-- PARTS AND COMPONENTS --\u003e\n\u003cp\u003e###\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1286\/9985\/files\/VERTPDIA_1024x1024.jpg?v=1733500608\" alt=\"\" style=\"float: none;\"\u003e\u003c\/div\u003e\n\n\u003c!-- INSTALLATION INSTRUCTIONS --\u003e\n\u003cp\u003e###\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1286\/9985\/files\/NVSERIES.pdf?v=1734121666\"\u003eInstallation Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"installation-instructions\"\u003e\n\u003ch2\u003eInstallation Instructions for NV120B3-2FE1T Vertical Pump\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePreparation:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eInspect the pump and motor for damage during shipping. Report any visible damage to the carrier or dealer.\u003c\/li\u003e\n\u003cli\u003eEnsure the installation site is level, stable, and provides sufficient space and ventilation for motor cooling and servicing.\u003c\/li\u003e\n\u003cli\u003eVerify that the pump model matches the system requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting the Pump:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eSecure the pump base to a solid, flat surface to prevent vibrations during operation.\u003c\/li\u003e\n\u003cli\u003eAlign and support the suction and discharge piping to avoid strain on the pump.\u003c\/li\u003e\n\u003cli\u003eInstall isolation valves on both the suction and discharge sides for easier maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePiping Connections:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure piping matches the pump’s 3\" ANSI 150# flanged connections.\u003c\/li\u003e\n\u003cli\u003eInstall gaskets to prevent leaks, ensuring they do not obstruct flow.\u003c\/li\u003e\n\u003cli\u003eRemove protective covers or caps from the flanges before installation.\u003c\/li\u003e\n\u003cli\u003eFor hot water applications, install a bleed valve in the discharge line to relieve pressure during maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Connection:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eHave a certified electrician verify that the electrical supply matches the motor’s specifications (10 HP, three-phase).\u003c\/li\u003e\n\u003cli\u003eEnsure proper motor wiring and confirm counterclockwise rotation when viewed from the motor’s rear.\u003c\/li\u003e\n\u003cli\u003eIf the rotation is incorrect, reverse any two leads on a three-phase motor to correct it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePriming the Pump:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eRemove the fill plug and use a funnel to fill the pump casing with water.\u003c\/li\u003e\n\u003cli\u003eOpen the vent plug to allow air to escape as the pump fills with water.\u003c\/li\u003e\n\u003cli\u003eRe-seal the vent plug and fill plug once a steady stream of water flows from the vent.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInitial Testing:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eOpen the suction valve fully and partially open the discharge valve.\u003c\/li\u003e\n\u003cli\u003eApply power to the motor and monitor for smooth operation without noise or vibration.\u003c\/li\u003e\n\u003cli\u003eGradually open the discharge valve to achieve desired operating conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Precautions:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eNever operate the pump without water, as it can cause damage to internal components.\u003c\/li\u003e\n\u003cli\u003eReplace coupling guards after installation to prevent injuries.\u003c\/li\u003e\n\u003cli\u003eEnsure the pump is properly grounded and connections are secure before starting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e","brand":"Crystal Quest Water Filters","offers":[{"title":"Default Title","offer_id":46077342220529,"sku":"CQE-PM-89008","price":6281.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/5711\/6312\/files\/nv120b3-2fe1t-vertical-pump-10-hp-crystal-quest-water-filters-36808305606749.jpg?v=1744956685","url":"https:\/\/villohome.com\/products\/nv120b3-2fe1t-vertical-pump-10-hp","provider":"Villohome","version":"1.0","type":"link"}