{"product_id":"nv120b3-2fe3t-vertical-pump-10hp","title":"NV120B3-2FE3T Vertical Pump (10HP)","description":"\u003cdiv class=\"product-description\"\u003e\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eNV120B3-2FE3T Vertical Pump\u003c\/strong\u003e is a high-capacity, multi-stage booster pump designed to meet the rigorous demands of industrial, commercial, and agricultural applications. Its vertical, in-line design optimizes space usage while delivering exceptional efficiency and reliability.\u003c\/p\u003e\n\u003cp\u003eFeaturing a powerful 10 HP, three-phase motor, this pump delivers a flow rate of up to 120 GPM and handles pressures up to 232 PSI. Constructed entirely from 304 stainless steel, it ensures outstanding durability and resistance to corrosion, making it ideal for use in harsh environments. Maintenance-free cartridge mechanical seals and ANSI standard flanged connections simplify installation and maintenance, minimizing downtime.\u003c\/p\u003e\n\u003cp\u003eCertified to meet NSF\/ANSI 61 and 372 standards, the NV120B3-2FE3T is well-suited for applications such as reverse osmosis, water boosting, filtration systems, heat exchangers, and hot and cold water circulation. Engineered for high performance and reliability, this pump is a dependable choice for your water handling needs.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- SPECIFICATIONS --\u003e\n\u003c!-- COMMENTED OUT UNTIL DATA IS ACCURATE --\u003e\n\u003cp\u003e###\u003c\/p\u003e\n\u003c!-- \u003cdiv class=\"product-specifications\"\u003e\n\u003ch2\u003eSpecifications for NV120B3-2FE3T Vertical Pump\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"10\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNV120B3-2FE3T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 HP, Three-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlow Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 120 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e232 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterials\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBody:\u003c\/strong\u003e 304 Stainless Steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpellers:\u003c\/strong\u003e 304 Stainless Steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiffusers:\u003c\/strong\u003e 304 Stainless Steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShaft:\u003c\/strong\u003e 431 Stainless Steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Seals:\u003c\/strong\u003e Silicon Carbide\/Silicon Carbide\/EPDM\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\" ANSI 150# Flanged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 248°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSF\/ANSI 61 and 372\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eReverse Osmosis\u003c\/li\u003e\n\u003cli\u003eWater Boosting\u003c\/li\u003e\n\u003cli\u003eFiltration Systems\u003c\/li\u003e\n\u003cli\u003eHot and Cold Water Circulation\u003c\/li\u003e\n\u003cli\u003eHeat Exchangers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump Length:\u003c\/strong\u003e 36.8 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 185 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e --\u003e\n\n\u003c!-- PARTS AND COMPONENTS --\u003e\n\u003cp\u003e###\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1286\/9985\/files\/VERTPDIA_1024x1024.jpg?v=1733500608\" alt=\"\" style=\"float: none;\"\u003e\u003c\/div\u003e\n\n\u003c!-- INSTALLATION INSTRUCTIONS --\u003e\n\u003cp\u003e###\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1286\/9985\/files\/NVSERIES.pdf?v=1734121666\"\u003eInstallation Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"installation-instructions\"\u003e\n\u003ch2\u003eInstallation Instructions for NV120B3-2FE3T Vertical Pump\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePreparation:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eInspect the pump and motor for visible damage during shipping. Report any issues to the carrier or dealer immediately.\u003c\/li\u003e\n\u003cli\u003eEnsure the installation site is level, stable, and provides adequate space and ventilation for motor cooling and maintenance.\u003c\/li\u003e\n\u003cli\u003eVerify that the pump model and motor specifications match the system requirements and application.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting the Pump:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eSecure the pump base to a flat, solid surface to minimize vibrations during operation.\u003c\/li\u003e\n\u003cli\u003eAlign and support the suction and discharge piping to prevent excessive strain on the pump.\u003c\/li\u003e\n\u003cli\u003eInstall isolation valves on both the suction and discharge sides for easier servicing and maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePiping Connections:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure piping matches the pump’s 3\" ANSI 150# flanged connections.\u003c\/li\u003e\n\u003cli\u003eInstall gaskets to prevent leaks and ensure proper sealing.\u003c\/li\u003e\n\u003cli\u003eRemove any protective covers or caps from the flanges before installation.\u003c\/li\u003e\n\u003cli\u003eInclude a bleed valve in the discharge line for hot water systems to relieve pressure during servicing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Connection:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eHave a certified electrician verify the electrical supply matches the motor’s specifications (10 HP, three-phase).\u003c\/li\u003e\n\u003cli\u003eEnsure correct motor wiring and confirm counterclockwise rotation when viewed from the motor’s rear.\u003c\/li\u003e\n\u003cli\u003eIf rotation is incorrect, reverse any two leads on a three-phase motor to correct it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePriming the Pump:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eRemove the fill plug and fill the pump casing with water using a funnel.\u003c\/li\u003e\n\u003cli\u003eOpen the vent plug to allow air to escape as the pump fills with water.\u003c\/li\u003e\n\u003cli\u003eRe-seal the vent and fill plugs once a steady stream of water flows from the vent.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInitial Testing:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eFully open the suction valve and partially open the discharge valve.\u003c\/li\u003e\n\u003cli\u003eApply power to the motor and monitor for smooth operation without unusual noise or vibration.\u003c\/li\u003e\n\u003cli\u003eGradually open the discharge valve to achieve the desired operating conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Precautions:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eNever operate the pump without water to avoid damaging internal components.\u003c\/li\u003e\n\u003cli\u003eReplace coupling guards after installation to ensure operator safety.\u003c\/li\u003e\n\u003cli\u003eEnsure the pump is properly grounded and all connections are secure before starting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e","brand":"Crystal Quest Water Filters","offers":[{"title":"Default Title","offer_id":46077389799665,"sku":"CQE-PM-89015","price":9814.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/5711\/6312\/files\/nv120b3-2fe3t-vertical-pump-10hp-crystal-quest-water-filters-36838306578525.jpg?v=1744956697","url":"https:\/\/villohome.com\/products\/nv120b3-2fe3t-vertical-pump-10hp","provider":"Villohome","version":"1.0","type":"link"}