{"product_id":"nv12b10fe3t-nv-cp-12-10-304ss-2hp-3hp","title":"NV12B10FE3T\/NV CP 12\/10 304SS 2HP\/3HP","description":"\u003cdiv class=\"product-description\"\u003e\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eNV12B10FE3T\/NV CP 12\/10 Vertical Pump\u003c\/strong\u003e is a robust and high-efficiency multistage booster pump designed for demanding industrial, commercial, and agricultural applications. Built with precision and durability in mind, its compact, in-line design ensures efficient space utilization and reliable performance in a variety of systems.\u003c\/p\u003e\n\u003cp\u003eFeaturing a 2 HP or 3 HP motor option, this pump delivers a flow rate of up to 12 GPM and handles pressures up to 362 PSI. Constructed entirely of 304 stainless steel, it offers exceptional corrosion resistance and long service life. Maintenance-free cartridge mechanical seals and ANSI standard flanged connections make installation and servicing simple and efficient.\u003c\/p\u003e\n\u003cp\u003eCertified to meet NSF\/ANSI 61 and 372 standards, this pump is ideal for reverse osmosis, water boosting, filtration systems, hot and cold water circulation, and heat exchangers. Its durable construction and high performance make it a trusted choice for a wide range of applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- SPECIFICATIONS --\u003e\n\u003c!-- COMMENTED OUT UNTIL DATA IS ACCURATE --\u003e\n\u003cp\u003e###\u003c\/p\u003e\n\u003c!-- \u003cdiv class=\"product-specifications\"\u003e\n\u003ch2\u003eSpecifications for NV12B10FE3T\/NV CP 12\/10 Vertical Pump\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\" cellspacing=\"0\" cellpadding=\"10\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNV12B10FE3T \/ NV CP 12\/10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 HP or 3 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlow Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 12 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e362 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterials\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBody:\u003c\/strong\u003e 304 Stainless Steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpellers:\u003c\/strong\u003e 304 Stainless Steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiffusers:\u003c\/strong\u003e 304 Stainless Steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShaft:\u003c\/strong\u003e 431 Stainless Steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Seals:\u003c\/strong\u003e Silicon Carbide\/Silicon Carbide\/EPDM\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\" ANSI 150# Flanged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 248°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSF\/ANSI 61 and 372\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eReverse Osmosis\u003c\/li\u003e\n\u003cli\u003eWater Boosting\u003c\/li\u003e\n\u003cli\u003eFiltration Systems\u003c\/li\u003e\n\u003cli\u003eHeat Exchangers\u003c\/li\u003e\n\u003cli\u003eHot and Cold Water Circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump Length:\u003c\/strong\u003e 25.4 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 72 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e --\u003e\n\n\u003c!-- PARTS AND COMPONENTS --\u003e\n\u003cp\u003e###\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1286\/9985\/files\/VERTPDIA_1024x1024.jpg?v=1733500608\" alt=\"\" style=\"float: none;\"\u003e\u003c\/div\u003e\n\n\u003c!-- INSTALLATION INSTRUCTIONS --\u003e\n\u003cp\u003e###\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1286\/9985\/files\/NVSERIES.pdf?v=1734121666\"\u003eInstallation Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"installation-instructions\"\u003e\n\u003ch2\u003eInstallation Instructions for NV12B10FE3T\/NV CP 12\/10 Vertical Pump\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePreparation:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eInspect the pump and motor for any visible damage during shipping. Report any damage to the carrier or dealer immediately.\u003c\/li\u003e\n\u003cli\u003eEnsure the installation site is level, stable, and provides adequate ventilation for motor cooling and servicing.\u003c\/li\u003e\n\u003cli\u003eVerify that the pump model matches the system requirements and intended application.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting the Pump:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eSecure the pump base to a flat, solid surface to minimize vibrations during operation.\u003c\/li\u003e\n\u003cli\u003eAlign and support the suction and discharge piping to prevent undue strain on the pump.\u003c\/li\u003e\n\u003cli\u003eInstall isolation valves on both the suction and discharge sides for easy maintenance and servicing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePiping Connections:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure piping matches the pump’s 2\" ANSI 150# flanged connections.\u003c\/li\u003e\n\u003cli\u003eInstall appropriate gaskets to prevent leaks and ensure unobstructed flow.\u003c\/li\u003e\n\u003cli\u003eRemove any protective covers or caps from the flanges before installation.\u003c\/li\u003e\n\u003cli\u003eFor hot water systems, include a bleed valve in the discharge line to relieve pressure during maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Connection:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eHave a certified electrician verify that the electrical supply matches the motor’s specifications (2 HP or 3 HP).\u003c\/li\u003e\n\u003cli\u003eEnsure proper motor wiring and confirm counterclockwise rotation when viewed from the motor’s rear.\u003c\/li\u003e\n\u003cli\u003eIf rotation is incorrect on a three-phase motor, reverse any two leads to correct it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePriming the Pump:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eRemove the fill plug and use a funnel to fill the pump casing with water.\u003c\/li\u003e\n\u003cli\u003eOpen the vent plug to allow air to escape as the pump fills with water.\u003c\/li\u003e\n\u003cli\u003eRe-seal the vent plug and fill plug once a steady stream of water flows from the vent.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInitial Testing:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eOpen the suction valve fully and partially open the discharge valve.\u003c\/li\u003e\n\u003cli\u003eApply power to the motor and check for smooth operation without noise or vibration.\u003c\/li\u003e\n\u003cli\u003eGradually open the discharge valve to achieve desired operating conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Precautions:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eNever operate the pump without water to prevent damage to internal components.\u003c\/li\u003e\n\u003cli\u003eReplace coupling guards after installation to ensure operator safety.\u003c\/li\u003e\n\u003cli\u003eEnsure the pump is properly grounded and all connections are secure before starting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e","brand":"Crystal Quest Water Filters","offers":[{"title":"Default Title","offer_id":46077384950001,"sku":"785084005461","price":4240.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/5711\/6312\/files\/nv12b10fe3t-nv-cp-12-10-304ss-2hp-3hp-crystal-quest-water-filters-36814563770461.jpg?v=1744956695","url":"https:\/\/villohome.com\/products\/nv12b10fe3t-nv-cp-12-10-304ss-2hp-3hp","provider":"Villohome","version":"1.0","type":"link"}