{"product_id":"nv45b4fe3t-vertical-pump-1","title":"NV45B4FE3T Vertical Pump","description":"\u003cdiv class=\"product-description\"\u003e\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eNV45B4FE3T Vertical Pump\u003c\/strong\u003e is a reliable and high-performing booster pump designed for demanding industrial, commercial, and agricultural applications. Its vertical, in-line design saves space while providing robust performance and easy integration into existing systems.\u003c\/p\u003e\n\u003cp\u003eEquipped with a 3 HP, three-phase motor, this pump delivers a flow rate of up to 45 GPM and a maximum pressure of 232 PSI. Constructed from durable 304 stainless steel, the NV45B4FE3T resists corrosion and ensures a long service life even in challenging environments. It also features maintenance-free cartridge mechanical seals and ANSI standard flanged connections for easy installation and maintenance.\u003c\/p\u003e\n\u003cp\u003eCertified to meet NSF\/ANSI 61 and 372 standards, the NV45B4FE3T is perfect for reverse osmosis, water boosting, filtration systems, hot and cold water circulation, and sprinkler systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- SPECIFICATIONS --\u003e\n\u003c!-- COMMENTED OUT UNTIL DATA IS ACCURATE --\u003e\n\u003cp\u003e###\u003c\/p\u003e\n\u003c!-- \u003cdiv class=\"product-specifications\"\u003e\n\u003ch2\u003eSpecifications for NV45B4FE3T Vertical Pump\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\" cellspacing=\"0\" cellpadding=\"10\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNV45B4FE3T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlow Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 to 65 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e232 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterials\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBody:\u003c\/strong\u003e 304 Stainless Steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpellers:\u003c\/strong\u003e 304 Stainless Steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiffusers:\u003c\/strong\u003e 304 Stainless Steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShaft:\u003c\/strong\u003e 431 Stainless Steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Seals:\u003c\/strong\u003e Silicon Carbide\/Silicon Carbide\/EPDM\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\" ANSI 150# Flanged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 248°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNSF\/ANSI 61 and 372\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eReverse Osmosis\u003c\/li\u003e\n\u003cli\u003eWater Boosting\u003c\/li\u003e\n\u003cli\u003eFiltration Systems\u003c\/li\u003e\n\u003cli\u003eHot and Cold Water Circulation\u003c\/li\u003e\n\u003cli\u003eSprinkler Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump Length:\u003c\/strong\u003e 33.33 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 126 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e --\u003e\n\n\u003c!-- PARTS AND COMPONENTS --\u003e\n\u003cp\u003e###\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"float: none;\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1286\/9985\/files\/VERTPDIA_1024x1024.jpg?v=1733500608\"\u003e\u003c\/div\u003e\n\n\u003c!-- INSTALLATION INSTRUCTIONS --\u003e\n\u003cp\u003e###\u003c\/p\u003e\n\u003cdiv class=\"installation-instructions\"\u003e\n  \u003ch2\u003eInstallation Instructions for NV45B4FE3T Vertical Pump\u003c\/h2\u003e\n  \u003col\u003e\n    \u003cli\u003e\n      \u003cstrong\u003ePreparation:\u003c\/strong\u003e\n      \u003cul\u003e\n        \u003cli\u003eInspect the pump and motor for any visible damage during shipping. Report any damage to the carrier or dealer.\u003c\/li\u003e\n        \u003cli\u003eEnsure the installation site is level, stable, and provides adequate space and ventilation for service and cooling.\u003c\/li\u003e\n        \u003cli\u003eVerify that the pump model matches the system specifications and is suitable for the intended application.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n      \u003cstrong\u003eMounting the Pump:\u003c\/strong\u003e\n      \u003cul\u003e\n        \u003cli\u003eSecure the pump base to a flat, solid surface to prevent vibration during operation.\u003c\/li\u003e\n        \u003cli\u003eAlign and support suction and discharge piping to avoid excessive strain on the pump.\u003c\/li\u003e\n        \u003cli\u003eInstall isolation valves on both the suction and discharge sides for easier maintenance.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n      \u003cstrong\u003ePiping Connections:\u003c\/strong\u003e\n      \u003cul\u003e\n        \u003cli\u003eEnsure piping matches the pump’s flanged connections (2\" ANSI 150#).\u003c\/li\u003e\n        \u003cli\u003eInstall appropriate gaskets to prevent leaks, ensuring they do not restrict flow.\u003c\/li\u003e\n        \u003cli\u003eRemove any protective covers or caps from the flanges before installation.\u003c\/li\u003e\n        \u003cli\u003eFor hot water systems, include a bleed valve in the discharge line to relieve pressure during maintenance.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n      \u003cstrong\u003eElectrical Connection:\u003c\/strong\u003e\n      \u003cul\u003e\n        \u003cli\u003eHave a certified electrician verify that the power supply matches the motor’s specifications (3 HP, three-phase).\u003c\/li\u003e\n        \u003cli\u003eEnsure proper motor wiring and check for counterclockwise rotation when viewed from the motor’s rear.\u003c\/li\u003e\n        \u003cli\u003eIf rotation is incorrect on a three-phase motor, reverse any two leads to correct it.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n      \u003cstrong\u003ePriming the Pump:\u003c\/strong\u003e\n      \u003cul\u003e\n        \u003cli\u003eRemove the fill plug and use a funnel to fill the pump casing with water.\u003c\/li\u003e\n        \u003cli\u003eOpen the vent plug to allow air to escape as the pump fills with water.\u003c\/li\u003e\n        \u003cli\u003eRe-seal the vent plug and fill plug once a steady stream of water flows from the vent.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n      \u003cstrong\u003eTesting the Pump:\u003c\/strong\u003e\n      \u003cul\u003e\n        \u003cli\u003eOpen the suction valve fully and partially open the discharge valve.\u003c\/li\u003e\n        \u003cli\u003eApply power to the motor and check for smooth operation without unusual noise or vibration.\u003c\/li\u003e\n        \u003cli\u003eGradually open the discharge valve to reach desired operating conditions.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n      \u003cstrong\u003eSafety Precautions:\u003c\/strong\u003e\n      \u003cul\u003e\n        \u003cli\u003eNever operate the pump without water to prevent damage to internal components.\u003c\/li\u003e\n        \u003cli\u003eAlways replace coupling guards after installation to prevent injuries.\u003c\/li\u003e\n        \u003cli\u003eEnsure the pump is properly grounded and all connections are secure before starting.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/li\u003e\n  \u003c\/ol\u003e\n\u003c\/div\u003e\n","brand":"Crystal Quest Water Filters","offers":[{"title":"Default Title","offer_id":46077389996273,"sku":"sku-42923631935581","price":6055.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/5711\/6312\/files\/nv45b4fe3t-vertical-pump-crystal-quest-water-filters-36775682375773.jpg?v=1744956696","url":"https:\/\/villohome.com\/products\/nv45b4fe3t-vertical-pump-1","provider":"Villohome","version":"1.0","type":"link"}